Abstrakt
Background: Since the first report on device closure of Patent Ductus Arteriosus (PDA) by Porstmann et al in 1967, the procedure has gained wide acceptance and has been used all over the world, including parts of Africa. The advantages when compared to surgical closure include shorter procedure time and hospital stay and no scar being left. This mode of treatment was not available in Nigeria prior to this with patients having to travel abroad to benefit.
Patient and method: Cardiac catheterisation laboratory became available in Lagos, Nigeria in 2009 and in October 2010, the laboratory collaborated with Lagos State University College of Medicine (LASUCOM) and /Lagos State University Teaching Hospital (LASUTH), to perform a device closure on a 3-year old girl with PDA who had presented to LASUTH with heart failure at the age of 6 months. To the best of our knowledge, this is the first time the procedure has been performed in Nigeria
Results: The patient made a successful recovery and is haemodynamically stable, on no medications.
Conclusion: Device closure of PDA is now safe and available in Nigeria.
Keywords: Patent ductus arteriosus, transcatheter closure, Nigeria.
Abstrait
Contexte: Depuis le premier rapport sur la fermeture par dispositif du canal artériel (PDA) par Porstmann et al en 1967, la procédure a été largement accepté et a été adoptée partout dans le monde, y compris certaines parties de l’Afrique. Comparant les avantages à ceux de la fermeture chirurgicale, on y trouve des procédures à courte durée et des hospitalisations à court séjour et aucune trace. Ce type de traitement n’existait pas au Nigeria et les patients devaient voyager à l’étranger pour en bénéficier. Patient Et methode: Le laboratoire cathétérisme cardiaque a débuté à Lagos, au Nigeria en 2009 et en Octobre 2010, le laboratoire a collaboré avec la faculté de médecine de l’Université de Lagos (LASUCOM) et le Centre hospitalier universitaire (LASUTH) de l’Etat de Lagos pour effectuer une fermeture par dispositif sur une fillette de 3 ans avec un PDA, qui a été présentée à LASUTH comme souffrant d’une insuffisance cardiaque depuis l’âge de 6 mois. Pour autant qu’on le sache, c’est la première fois que cette procédure a été effectuée au Nigeria.
Résultats: Le patient a fait une récupérationréussie et est hémodynamiquementstable, n’ayant utilisé aucun médicament.
Correspondence: Dr. BA Animashaun, Department of Paediatrics and Child Health, Lagos State University College of Medicine, Ikeja, Lagos, Nigeria. E-mail: deoladebo@yahoo.com
Reference
Postmann W, Wierny L and Warnke H. Closure of the Patent ductus arteriosus without thoracotomy. Ger Med Mon. 1967;12: 259-261.
Michael M, Brook MD, Michael M and Heyman MD. Patent Ductus Arteriosus. In: Moss Adams Heart disease in Infants, Children and Adolescents. 5th ed. Baltimore: William and Wilkins, 1995.p. 746-764.
Antia AU. Congenital heart disease in Nigeria. Arch of Diseases in Childhood 1974;49:36-39.
Okoromah CAN, Ekure EN, OJo OO, Animasahun BA and Bastos MI. Structural Heart Disease in Children in Lagos: Profile, Problems and Prospects. The Nigerian Postgraduate Medical Journal 2008; 15:82-31.
Laborde F, Folliguet TA, Etienne PY, et al. Video-thoracoscopic surgical interruption of patent ductus arteriosus. Routine experience in 332 pediatric cases. Eur J Cardiothorac Surg 1997;11:1052-1105.
Vanamo K, Berg E, Kokki H, et al. Video-assisted thoracoscopic versus open surgery for persistent ductus arteriosus. J Pediatr Surg 2006;41: 1226-1229.
Sato K, Fujino M, Kozuka T, Naito Y, Kitamura S, Nakano S, Ohyama C and Kawashima Y. Transfemoral plug closure of patent ductus arteriosus. Experiences in 61 consecutive cases treated without thoracotomy. Circulation. 1975;51: 337-341.
AMPLATZER Duct Occluder Patient Guide by AGA medical corporation MM00318 (02) Global 04/08
Chen ZY, Wu LM, Luo YK et al. Comparison of long-term clinical outcome between transcatheter Amplatzer occlusion and surgical closure of isolated patent ductus arteriosus. Chin Med J (Engl) 2009; 122(10):1123-1127.
Pass RH, Hijazi Z, Hsu DT et al. Multicenter USA Amplatzer patent ductus arteriosus occlusion device trial: initial and one-year results. J Am Coll Cardiol 2004; 44:513-519.